1.0 |
First version. |
1.1 |
Changed the conversion formulas
for the LATERAL ACCELERATION, LONGITUDINAL ACCEL and VERTICAL
ACCELERATION parameters so that the values produced by the program
exactly match the NTSB CSV files instead of having a maximum difference
of 1 in the last decimal place. Added the following parameters: BARO COR NO. 1 (inHg) BARO COR NO. 2 (inHg) BLEED DUCT PRESS - L (PSI) BLEED DUCT PRESS - R (PSI) BUS AC VOLTS - LEFT (VAC) BUS AC VOLTS - RIGHT (VAC) DENSITY S TANK (LB/GAL) DENSITY R TANK (LB/GAL) DENSITY L TANK (LB/GAL) DENSITY C TANK (LB/GAL) EICAS COMPUTER ENG N1-ACTUAL - L (%RPM) ENG N1-ACTUAL - R (%RPM) ENG N2-ACTUAL - L (%RPM) ENG N2-ACTUAL - R (%RPM) ENG N3-ACTUAL - L (%RPM) ENG N3-ACTUAL - R (%RPM) ENG DED GEN - L ENG DED GEN - R ENG EGT-LEFT (DEG C) ENG EGT-RIGHT (DEG C) ENG EGT RED - L ENG EGT RED - R ENG EPR COMMAND - L (RATIO) ENG EPR COMMAND - R (RATIO) ENG EPR LIMIT-L (RATIO) ENG EPR LIMIT-R (RATIO) ENG EPR-ACTUAL - L (RATIO) ENG EPR-ACTUAL - R (RATIO) ENG FUEL FLOW - L (LBS/HR) ENG FUEL FLOW - R (LBS/HR) ENG LO OIL PRESS - L ENG LO OIL PRESS - R ENG OIL PRES - L (PSI) ENG OIL PRES - R (PSI) ENG OIL PRESS RED - L ENG OIL PRESS RED - R ENG OIL QTY - L (US PINT) ENG OIL QTY - R (US PINT) ENG OIL TEMP - L (DEG C) ENG OIL TEMP - R (DEG C) ENG OIL TEMP RED - L ENG OIL TEMP RED - R ENG OUT RLY - L ENG OUT RLY - R ENG N1 RED - L ENG N1 RED - R ENG N2 RED - L ENG N2 RED - R ENG N3 RED - L ENG N3 RED - R ENG VIBRATION - L (SCALAR) ENG VIBRATION - R (SCALAR) ENGINE OUT (EO) - L ENGINE OUT (EO) - R EPR BUG DRIVE LEFT (RATIO) EPR BUG DRIVE RIGHT (RATIO) EPR TARGET-FMC (RATIO) FAN INLET TOTAL TEMP - L (DEG C) FAN INLET TOTAL TEMP - R (DEG C) FILTER 1 VIB - L (SCALAR) FILTER 1 VIB - R (SCALAR) FILTER 2 VIB - L (SCALAR) FILTER 2 VIB - R (SCALAR) FILTER 3 VIB - L (SCALAR) FILTER 3 VIB - R (SCALAR) FMC/IRU DATA SOURCE AFT FUEL PUMP - L AFT FUEL PUMP - R C-L FUEL PUMP LT C-L FUEL PUMP PR C-R FUEL PUMP LT C-R FUEL PUMP PR FWD FUEL PUMP FWD ACCESS DR GROUNDSPEED CAPT (KNOTS) HYD ELEC PUMP OVHT - L HYD ELEC PUMP OVHT - R HYD PRES - C (PSI) HYD PRES - L (PSI) HYD PRES - R (PSI) HYD PRI PUMP OVHT - LEFT HYD PRI PUMP OVHT - RIGHT HYD PUMP 1 OVHT - CENTER HYD PUMP 2 OVHT - CENTER HYD RSVR PRESS < 17 - C HYD RSVR PRESS < 17 - L HYD RSVR PRESS < 17 - R HYD RSVR PRESS > 55 - C HYD RSVR PRESS > 55 - L HYD RSVR PRESS > 55 - R HYD SYS LO PRESS - C HYD SYS LO PRESS - L HYD SYS LO PRESS - R IAS FCC L-A-4 IAS FCC R-A-4 IAS FCC C-A-4 IAS LIMIT OPER FCC L-A-4 IAS LIMIT OPER FCC R-A-4 IAS LIMIT OPER FCC C-A-4 IAS MODE OPER MAIN CARGO DOOR MASTER CAUTION LIGHT MASTER WARNING CAPT MASTER WARNING F/O N2 CORRECTED TO 2.5 - L (% RPM) N2 CORRECTED TO 2.5 - R (% RPM) PITCH ANGLE F/O (DEG) PITCH ANGLE CAPT (DEG) Super Frame Number R TANK LB/KG S TANK LB/KG C TANK LB/KG L TANK LB/KG TCAS FAILURE TCAS SYSTEM STATUS TRACK ANGLE TRUE (DEG) TRUE AIRSPEED (KT) VHF CENTER KEYING VHF LEFT KEYING VHF RIGHT KEYING VOR FREQUENCY-LEFT (MHz) VOR FREQUENCY-RIGHT (MHz) For further information see Notes on Parameters for the AAL77 FDR Decoder. |
1.2 |
Added the following parameters: A/P CAUTION FCC L-A-4 A/P CAUTION FCC R-A-4 A/P CAUTION FCC C-A-4 AUTOLAND WARN LT FCC L-A-4 AUTOLAND WARN LT FCC R-A-4 AUTOLAND WARN LT FCC C-A-4 CAPT CONT COLUMN POSN (DEG) CAPT CONT WHEEL POSN (DEG) FLAP HANDLE POSN (DEG) FLAP HANDLE POSN Voltage (V) GPWC FAILURE LAND 2 (GREEN) FCC L-A-4 LAND 2 (GREEN) FCC R-A-4 LAND 2 (GREEN) FCC C-A-4 LAND 3 (GREEN) FCC L-A-4 LAND 3 (GREEN) FCC R-A-4 LAND 3 (GREEN) FCC C-A-4 MAINTENANCE REQUIRED - L MAINTENANCE REQUIRED - R Raw CAPT CONT COLUMN POSN Raw CAPT CONT WHEEL POSN Raw FLAP HANDLE POSN T/O CONFIG FLAPS T/O CONFIG PARK BRK TOTAL PRESSURE (mB) WINDSHEAR CAUTION For further information see Notes on Parameters for the AAL77 FDR Decoder. |
1.3 |
Added the following parameters: ACMS S/W P/N CODE AOA HEAT ON - #1 AOA HEAT ON - #2 AOA PROBE HEAT - L AOA PROBE HEAT - R IDLE THRUST OPER INDICATED AOA (DEG) FLT DECK DOOR MANDATORY S/W P/N CODE MANUFACTURER CODE VENDOR DATABASE CODE For further information see Notes on Parameters for the AAL77 FDR Decoder. |
1.4 |
Added the following parameters: FLT DIR - PITCH CAPT (DEG) FLT DIR - ROLL CAPT (DEG) FLT DIR ON-CAPT MCP A-A-2 FLT DIR ON-CAPT FCC L-A-4 FLT DIR ON-CAPT FCC R-A-4 FLT DIR ON-CAPT FCC C-A-4 FLT DIR ON-F/O MCP A-A-2 FLT DIR ON-F/O FCC L-A-4 FLT DIR ON-F/O FCC R-A-4 FLT DIR ON-F/O FCC C-A-4 FMA FAULT 1 (CWS) FCC L-A-4 FMA FAULT 1 (CWS) FCC R-A-4 FMA FAULT 1 (CWS) FCC C-A-4 FMA FAULT 2 (PTCH) FCC L-A-4 FMA FAULT 2 (PTCH) FCC R-A-4 FMA FAULT 2 (PTCH) FCC C-A-4 FMA FAULT 3 (ROLL) FCC L-A-4 FMA FAULT 3 (ROLL) FCC R-A-4 FMA FAULT 3 (ROLL) FCC C-A-4 ROLL ANGLE F/O (DEG) ROLL ANGLE CAPT (DEG) ROLL ARM FCC L-A-4 ROLL ARM FCC R-A-4 ROLL ARM FCC C-A-4 ROLL DISAGREE CAPT ROLL DISAGREE F/O ROLL ENGAGE DETENT CMD FCC L-A-4 ROLL ENGAGE DETENT CMD FCC R-A-4 ROLL ENGAGE DETENT CMD FCC C-A-4 ROLL TRIM CMD L WING DOWN ROLL TRIM CMD R WING DOWN ROLLOUT MODE OPER FCC L-A-4 ROLLOUT MODE OPER FCC R-A-4 ROLLOUT MODE OPER FCC C-A-4 For further information see Notes on Parameters for the AAL77 FDR Decoder. |
1.4.1 |
Added the following parameters: COMPAR ENABLE CAPT COMPAR ENABLE F/O COMPARATOR FAIL CAPT COMPARATOR FAIL F/O CON MODE OPER GROSS WEIGHT (LBS) HYD GENERATOR STRUT LOOP 1 - L STRUT LOOP 1 - R ENG OIL FILTER - L ENG OIL FILTER - R CTR ENTRY DOOR - L CTR ENTRY DOOR - R AUTOTHROTTLE DISC GEAR DOORS SYS 1 GEAR DOORS SYS 2 ECS PACK OFF - L ECS PACK OFF - R MAIN CARGO DOOR T.E. FLAP ASYM HYD ELEV VALVE - C HYD ELEV VALVE - L HYD ELEV VALVE - R FWD EQUIP SMOKE FIRE EXT SWITCH - L FIRE EXT SWITCH - R A/P T.E. FLAP POSITION FCC L-A-4 (DEG) A/P T.E. FLAP POSITION FCC R-A-4 (DEG) A/P T.E. FLAP POSITION FCC C-A-4 (DEG) CARGO FIRE SW B117 - PRE 97 RULE B118 - CUSTOMER UNIQUE FRAME B119 - FRAME SEL MSB B120 - FRAME SEL LSB Pressure Altitude as per 757-3b_1.TXT (FEET) LDG GEAR LEVER For further information see Notes on Parameters for the AAL77 FDR Decoder. |
1.5 |
Added an option to replace blank
(empty) values with null. Added the following parameters: ADC INVALID ADC SELECT CAPT ADC SELECT F/O ADC SELECT SW-CAPT MACH (MACH) MACH ENGAGED FCC L-A-4 MACH ENGAGED FCC R-A-4 MACH ENGAGED FCC C-A-4 MACH LIMIT OPER FCC L-A-4 MACH LIMIT OPER FCC R-A-4 MACH LIMIT OPER FCC C-A-4 MACH MODE OPER MACH SPEED TRIM OVERSPEED PULL UP TOTAL AIR TEMP (DEG C) STATIC AIR TEMP (DEG C) WIND SPEED (KNOTS) For further information see Notes on Parameters for the AAL77 FDR Decoder. |
1.6 |
Added the following parameters: A/C TYPE WIND DIRECTION TRUE (DEG) TRUE HEADING CAPT (DEG) For further information see Notes on Parameters for the AAL77 FDR Decoder. |
1.7 |
Removed the following parameters: DENSITY C TANK DENSITY L TANK DENSITY R TANK DENSITY S TANK Added the following parameters: CORRECTED AOA (DEG) Raw ALTITUDE (1013.25mB) COARSE Raw ALTITUDE (1013.25mB) FINE Raw CORRECTED AOA Raw INDICATED AOA For further information see Notes on Parameters for the AAL77 FDR Decoder. |
1.8 |
Added the following parameters: AILERON POSN-OUTER - L (DEG) AILERON POSN-OUTER - R (DEG) ALT HOLD MODE OPER FCC L-A-4 ALT HOLD MODE OPER FCC R-A-4 ALT HOLD MODE OPER FCC C-A-4 FL CH MODE OPER FCC L-A-4 FL CH MODE OPER FCC R-A-4 FL CH MODE OPER FCC C-A-4 G/S MODE OPER FCC L-A-4 G/S MODE OPER FCC R-A-4 G/S MODE OPER FCC C-A-4 Raw RUDDER PEDAL POSITION (DEG) Raw STAB POSITION SYNCHRO (DEG) RUDDER PEDAL POSITION (DEG) RUDDER POSITION (DEG) SINK RATE STAB POSITION SYNCHRO (DEG) T/O MODE OPER-P FCC L-A-4 T/O MODE OPER-P FCC R-A-4 T/O MODE OPER-P FCC C-A-4 TERRAIN OVERRIDE V NAV MODE OPER FCC L-A-4 V NAV MODE OPER FCC R-A-4 V NAV MODE OPER FCC C-A-4 V/S MODE FCC L-A-4 V/S MODE FCC R-A-4 V/S MODE FCC C-A-4 For further information see Notes on Parameters for the AAL77 FDR Decoder. Removed unnecessary trailing zeroes after the decimal point for some parameters. |
1.9 |
Added the following parameters: A/C NUMBER EICAS OPC PART NUM EICAS OPS PART NUM EICAS SELECT SW ENGINE IDENT FLEET IDENT Raw EICAS OPC PART NUM LSB Raw EICAS OPC PART NUM MSB Raw EICAS OPS PART NUM LSB Raw EICAS OPS PART NUM MSB For further information see Notes on Parameters for the AAL77 FDR Decoder. |
1.10 | Added the following parameters: A/P CMD C ENGA FCC L-A-4 A/P CMD C ENGA FCC R-A-4 A/P CMD C ENGA MCP A-A-2 A/P CMD C ENGA FCC C-A-4 A/P CMD L ENGA FCC L-A-4 A/P CMD L ENGA FCC R-A-4 A/P CMD L ENGA MCP A-A-2 A/P CMD L ENGA FCC C-A-4 A/P CMD R ENGA FCC L-A-4 A/P CMD R ENGA FCC R-A-4 A/P CMD R ENGA MCP A-A-2 A/P CMD R ENGA FCC C-A-4 A/P CWS C ENGA FCC L-A-4 A/P CWS C ENGA FCC R-A-4 A/P CWS C ENGA MCP A-A-2 A/P CWS C ENGA FCC C-A-4 A/P CWS L ENGA FCC L-A-4 A/P CWS L ENGA FCC R-A-4 A/P CWS L ENGA MCP A-A-2 A/P CWS L ENGA FCC C-A-4 A/P CWS R ENGA FCC L-A-4 A/P CWS R ENGA FCC R-A-4 A/P CWS R ENGA MCP A-A-2 A/P CWS R ENGA FCC C-A-4 A/P ENGAGE DETENT FCC L-A-4 A/P ENGAGE DETENT FCC R-A-4 A/P ENGAGE DETENT FCC C-A-4 A/P WARN-2 BAT A/P WARN-2 NORM A/P WARNING FCC L-A-4 A/P WARNING FCC R-A-4 A/P WARNING FCC C-A-4 ALTITUDE REPORTING AUTOPILOT ENGAGED HUD AUTOTHROTTLE ENGD HUD ENG THROTTLE - L ENG THROTTLE - R Raw THR LVR ANG / EQUIV PLA-L Raw THR LVR ANG / EQUIV PLA-R SPI THR LVR ANG / EQUIV PLA-L (DEG) THR LVR ANG / EQUIV PLA-R (DEG) THROTTLE HLD ANNUN THRUST MODE OPER THRUST REV POSN'N - L (% DEP) THRUST REV POSN'N - R (% DEP) For further information see Notes on Parameters for the AAL77 FDR Decoder. |